oh you know what, I was having a brain fart there. I was thinking the gain was done in software, I had forgotten the ATMEGA had actual internal gain circuitry.? as for the change in value, I think you can re-create what I am describing in a few simple steps.
?
Attach the scope to a stable voltage, in my case a disconnected sensor sitting at .182v (voltage read from physical scope in DMM mode)
plot this on the pc with gain slider in 4tth position from bottom
turn on horizontal curosr for the channel in question, align the cursor with the voltage, see VA reading of whatever (-.37 volts)
decrease? the gain slider on the pc one step
if the horizntaal curosr has shifted off the trace, re-align it and read the new voltage, it does not seem to move ever however
new Va reading is -.76
?
not sure why it is negative either.? also by the logic of my cursor, when the setting is 1.28 v/div, the horizontal cursor actually indicates 2.3v/div when I drag a cursor from one div to the next.? HOWEVER setting one cursor on one div and the other cursor on the next div, I get a reading like
Va -3v
Vb -5.3V
delta 1.3v
so the delta is right but the readouts are wrong....? I screencaped it for you.
?
I am in ubuntu 12.04