Xminilab Portable Curve Tracer Switch Suggestion

More
12 years 4 months ago - 12 years 4 months ago #896 by dbpage
I noticed the following tip in the XScopes User's Manual: Do not connect CH2 to a voltage source while the CURVE switch is on. Damage to the device will occur.
This is an incredibly easy mistake to make.
I suggest turning around the beautiful DPDT CURVE switch on the Xminilab Portable so that CH2 (and CH1 for that matter) disconnects the external input and connects the AWG output. This would make good use of the unused switch contacts and help prevent connecting CH2 to a voltage source while the CURVE switch is on.
?
?
?
Last edit: 12 years 4 months ago by dbpage. Reason: Clarify which switch

Please Log in or Create an account to join the conversation.

More
12 years 4 months ago #897 by ganzziani
I'm already using both switches on the DPDT: CH1 connects to the AWG thru a 1k, and CH2 connects to the AWG directly.

Please Log in or Create an account to join the conversation.

More
12 years 4 months ago - 12 years 4 months ago #898 by dbpage
The schematic in the manual makes it appear that there are unused NO terminals on the DPDT switch (look for the little "x" marks on p. 8). If the CH1 and CH2 internal inputs are connected to C on the switch instead of NC, and CH1 and CH2 external inputs are connected to NC, and AWG is connected to NO of each pole (one via the 1k resistor and the other direct), it would prevent a voltage on CH2 from causing damage. Is that possible, or is the schematic in the User's Manual incorrect?
Last edit: 12 years 4 months ago by ganzziani.

Please Log in or Create an account to join the conversation.

More
12 years 4 months ago - 12 years 4 months ago #899 by ganzziani
Here is the schematic:/\r\n/ www.gabotronics.com/download/xminilab-po...table-schematics.pdf
Ok, I see what you are suggesting. Let me practice some ASCII art:
Curve's DPDT Switch connection:
.________ CH1 Connector/\r\n/ //\r\n/ OPAMP CH1 ______./ .________ 1K - AWG/\r\n/ /\r\n/ .________ CH2 Connector/\r\n/ //\r\n/ OPAMP CH2 ______./ .________ AWG/\r\n/ /\r\n/
I remember trying something similar before, I had increased crosstalk from the AWG into the analog inputs, caused by the internal capacitance on the DPDT switch. There is more capacitance between the "C" and the "NC" or "NO" pins, than between the "NO" and "NC" pins. Because each channel has a 1Mohm input impedance, just a few picofarads of capacitance creates crosstalk.
It would be interesting to try again, perhaps on my next prototype build.
Last edit: 12 years 4 months ago by ganzziani.

Please Log in or Create an account to join the conversation.

More
12 years 4 months ago - 12 years 4 months ago #900 by dbpage
I can see how crosstalk may be an issue, but in either configuration, the AWG output is within millimeters of the 1M ohm analog input and stray capacitance could very well couple the free-running AWG output to the analog input. In the current configuration, the external analog input is always connected, and in the proposed configuration, the external analog input is disconnected. In both configurations, the internal analog input is always in close proximity with the AWG output. I prefer disconnecting the external input, and I hope the proposed configuration is successful in your next prototype build. Thanks for considering my proposal.
Last edit: 12 years 4 months ago by dbpage.

Please Log in or Create an account to join the conversation.

Time to create page: 0.096 seconds