What do the AWG Sweep Range numbers mean?

More
12 years 4 months ago #907 by dbpage
I understand that Frequency = Cycles * 125000/Period. With the curve switch ON and the oscilloscope timebase set to 128uS/div, when the sweep range is 1: 004 and 2: 060, the frequency sweeps from a little more than 1KHz to about 15.525KHz.
What do the numbers 1: and 2: mean?
Please help me convert 4 and 60 to approximately 1KHz and 15.525KHz.
Thanks!
/\r\n/

Please Log in or Create an account to join the conversation.

More
12 years 4 months ago #908 by dbpage
I am beginning to understand the range numbers./\r\n/1: Range is 0 to 255, but is not permitted to increase above 2:/\r\n/2: Range is 0 to 255, but decreasing 2: when 2: = 1: will adjust 1: down to prevent 1: > 2:/\r\n/The 0-255 range maps to the current scope timebase/FFT max frequency settings./\r\n//\r\n/I recommend updating the AWG section in the XScope User's Manual to describe the above./\r\n//\r\n/Thanks!/\r\n/

Please Log in or Create an account to join the conversation.

More
12 years 4 months ago #909 by ganzziani
Thanks for the suggestion, I'll add a note to the manual.

Please Log in or Create an account to join the conversation.