Xminilab in 'METER' mode, frequency display irregularities.

More
14 years 4 months ago #315 by Buzby
Hi,
I'm running Xminilab v 1.78, and using the dual frequency meter display mode.
I have an external 12.5Hz low frequency 5v squarewave connected to CH1, and the AWG connected to CH2.
At low AWG frequencies the dual frequency display looks OK.
But when the AWG frequency rises above 625Hz the 12.5Hz display changes to 25Hz.
I will be wanting to use the frequency meter to display two widely spaced frequencies, ( ~100Hz and ~38KHz )
Can the Xminilab do this ?. Is there an option I've missed ?.
Thanks,
Buzby
 
 
 
 
 
 
 
 
 

Please Log in or Create an account to join the conversation.

More
14 years 4 months ago #316 by ganzziani
The frequency meter range is determined by the highest frequency of the analog channels. If you have a high frequency on one channel and a low frequency on the other, the channel with the lowest frequency will have poor resolution. Try disconnecting the AWG on CH2.

On a future revision, I'll try to make the two channels frequency measuring independent.

Please Log in or Create an account to join the conversation.

More
14 years 4 months ago #317 by Buzby
Hi Gabriel,

Thanks for the quick reply !.

I really think that when the overall mode is 'METER', then that's what the module should be dedicated to.

( Also, the mini-display of the scope traces below the digits of the meter is not much use at all. )

Overall I am pleased with the Xminilab scope. I bought it to use on my breadboard when I'm away from my bench scope, and so far it's doing a good job.

Cheers,

Buzby

Please Log in or Create an account to join the conversation.

More
14 years 2 months ago #363 by ganzziani
Hi Buzby. The new Frequency counter could work for you, it is independent from the analog channels, has better resolution, and has a much wider range. However, it is only for digital signals.

Please Log in or Create an account to join the conversation.

More
14 years 2 months ago #364 by Joseph Levy
Hi
Updated to 1.89   (hw 2.2)
digital square wave 4 V pp (from zero to 4 volt)
Will count on Meter only to 255 Hz , at higher frequencies will display much too high!!

Please Log in or Create an account to join the conversation.

Time to create page: 0.093 seconds